Skip to main content
Pipit SC has the lowest peak track force
Access to
Target lesion
Access to
Distal lesion
Retrieval into
Guide catheter
Pipit SC has the best push efficiency at 1.0 N
Pipit SC has 6F KBT compatibility *

Proximal shaft: 1.73 F    Distal shaft: 2.67 F

Crossing profile: 0.72 mm/0.028" ( 2.5 x 15 mm balloon)

  Two Pipit SC balloon up to the size of 3.5 mm for all lengths, is 6F KBT compatible

  Two Pipit SC balloon distal shaft size is 5.34 F, which is less than 5.4 F

Crossability
Advanced multilayered balloon material

 Advanced multi-layered balloon material makes the balloon soft,with better shape memory

 Upon deflation the balloon rewraps into a tri-fold shape

 Pipit SC has a low rewrap profile of 1.84 mm

Selective hydrophilic coating

Enhanced crossability

Selective hydrophilic coating enhances the crossability

Effective and Precise dilatation

 Minimizes slippage,prevents melon seeding

 Enables precise dilatation

Technical specification
Balloon material Multi-layered polyamide
Balloon fold Tri-fold
Hydrophilic coating Selective hydrophilic coating at distal shaft including balloon tip
Balloon diameter 2.0 mm - 4.5 mm
Balloon length 9.0 mm - 30 mm
Tip entry profile 0.016"/0.41mm
Shaft diameter Proximal 1.73 F (2.00 mm - 2.75 mm), 2.01 F (3.00 mm - 4.50 mm)
Distal 2.67 F(2.00 mm-3.75 mm), 2.9 F ( 4.00 mm & 4.50 mm)
Catheter length 138 cm
Rapid exchange length 25 cm
Markers on the proximal shaft 85 cm and 95 cm
Maximum recommended guidewire 0.014"/ 0.36 mm
Guide catheter compatibility 5F compatible
KBT compatibility 6F ≤3.50 mm diameter and all lengths
Compliance chart
Pressure
[atm]
2.00
mm
2.25
mm
2.50
mm
2.75
mm
3.00
mm
3.50
mm
4.00
mm
4.50
mm
2 1.91 2.16 2.41 2.61 2.82 3.24 3.74 4.34
4 1.96 2.21 2.46 2.69 2.91 3.38 3.85 4.43
6 2.00 2.25 2.50 2.75 3.00 3.50 3.97 4.50
8 2.04 2.31 2.54 2.83 3.09 3.59 4.07 4.59
10 2.08 2.35 2.57 2.86 3.14 3.67 4.15 4.68
12 2.13 2.39 2.60 2.89 3.18 3.70 4.21 4.76
14 2.17 2.43 2.62 2.91 3.21 3.74 4.27 4.85
16 2.21 2.48 2.64 2.94 3.25 3.78 4.32 4.93
18 2.25 2.52 2.67 2.97 3.28 3.82 4.38 4.99
    Nominal Pressure         Rated Burst Pressure
Size matrix and ordering information
Diameter
(mm)
Length (mm)
9 12 15 20 25 30
2.00
2.25
2.50
2.75
3.00
3.50
4.00
4.50
Proposed size matrix for commercial purpose

* upto 3.5 mm diameter for all lengths.

NP = Nominal Pressure, RBP = Rated Burst Pressure, KBT = Kissing Balloon Technique

Disclaimer: Please note that the 6F KBT is CE approved. By accessing this content, users acknowledge their responsibility to ensure adherence to local laws and guidelines within their respective jurisdictions.

Pipit SC is a trademark of Sahajanand Medical Technologies Limited. Specifications are subject to modifications, revisions, and improvements. Bench test results may not necessarily be indicative of clinical performance. Tests performed by and data on file at Sahajanand Medical Technologies Limited. Testing was conducted on Pipit SC and respective brands with a 2.50 mm x 15 mm balloon. Data source: IFU/marketing collaterals of respective brands.